5.0 Optional settings
5.1 Network setup
Each network must contain one (and only one) master unit
(MAS).
• All other units must be either slave units (SLA) or independ-
ent units (ALO).
Independent units in the network will not respond to
or send information to a master unit. However, they still
count towards the network maximum of 32 units.
• The following settings on all slave units are controlled from
the master unit. All other settings must be configured on
each thermostat.
Time
Weekday
Economy set-back
• Network cables are unshielded, untwisted, and unpolarised
two-wire cables for easy installation.
• Maximum network cable length is 100 m (0.75 mm
2
wire